Portable conductivity meters EC-20 cond • EC 25 cond
- EC-20 cond
- Display Conductivity and Temperature simultaneously
- Automatic calibration 1 to 3 points between 4 conductivity standard values
- Manual calibration on 1 point (User defined)
- Large Display (backlight for EC-25 cond) with indication of standards used for calibration and stability
- Automatic and manual compensation of temperature with reference value 15...30 °C
- Waterproof IP57 protection
- Strong carrying case with all accessories to be used as a small portable laboratory
- additional for EC-25 cond
- TDS measurement with adjustable factor
- GLP
- Memory recall of last calibration with control of cell constant,date and time
- CAL DUE : set of calibration frequency for high quality measurements
- Data logger, manual and automatic with 500 memory values with date and time
- USB port to download data and power by Computer or power supply (included)
- Software PC-Link to download data (included)
- Conductivity Portable Meter EC-20 cond • EC-25 cond
- An elegant and ergonomic case, with a practical soft rubber andIP57 protection, has inside the best of technology.
- A large display (backlight for EC-25 COND) shows all information that you need about the measurement, cell‘s life and instrument‘s memory.
- All the functional parameters of connected cell, during measurement or calibration, are constantly checked and inform theoperator for easy trouble-shooting.
- Only 4 keys for COND 7 (6 for EC-25 cond) allow the user to control all functions in an intuitive and easy way.
- A practical USB port (EC-25-cond), covered to guarantee waterproof protection, allow to download data (with date of last calibration done) or power the instruments by Computer or with power supply 220V/USB included.
Specifications | EC-20 cond | EC-25 cond |
Measuring Range (cond) | 0,00 - 20,00 - 200,0 - 2000 µS 2,00 - 20,00 - 200,0 m | 0,00 - 20,00 - 200,0 - 2000 µS 2,00 - 20,00 - 200,0 m |
Resolution (cond) | 0,01/0,1/1 µS 0,01/0,1 mS | 0,01/0,1/1 µS 0,01/0,1 mS |
Calibration Standards | 84, 1413 µS, 12.88, 111.8 mS, User | 84, 1413 µS, 12.88, 111.8 mS, User |
Calibration points | 1...4 | 1...4 |
Cell constant selectable (cm-1) | 0,1 – 1 – 10 | 0,1 – 1 – 10 |
Reference Temp. (°C) | 15...30 | 15...30 |
Temperature compens.(%/°C) | 0,00...10,00 | 0,00...10,00 |
Measuring Range (°C) | 0...100,0 | 0...100,0 |
Resolution (°C) | ± 0,5 | ± 0,5 |
TDS-Measuring Range (g/l) | 0..100 | 0..100 |
TDS-Factor | 0,4...1 | 0,4...1 |
Salinity (ppt) | No | 0..50 |
Memory | No | 500 Data |
Timer | No | Yes |
GLP | No | Yes |
Interface | No | Yes |
Display | LCD | LCD, 3 color backlit display |
IP-Protection | IP 57 | IP 57 |
Power | Battery | Battery |
Weight (g) | 295 | 295 |
Dimmensions (mm) | 86 x 196 x 33 | 86 x 196 x 33 |